ISO 180
IZOD Impact
Purpose: This test method is used to determine the Izod impact resistance of a solid polymer from a pendulum swing.
Sample: 80 x 10 x 4 mm
Price & Delivery: Contact us for a quote.
Basic Description: A notched test specimen is clamped into impact machine. The pendulum is then released and the energy is recorded.
Limitations: 23 J maximum potential energy
Method Publisher: https://www.iso.org/obp/ui/#iso:std:iso:180:ed-5:v1:en
Keywords:
- Izod impact energy
- Charpy impact
- Notched impact
- Unnotched impact
Related Test Methods:
- ASTM D4226 – Impact Resistance
- ASTM D256 – Izod Impact
- ASTM D4812 – Unnotched Impact
- ASTM D6110 – Charpy Impact
- ISO 179 – Charpy Impact